TESTER MICROPROCESSOR FORMULA 2K

PURPOSE AND APPLICATION

The FORMULA® 2K ester is an automated universal measurement and control system for the functional and parametric control of digital, analog and digital-analog microcircuits of small and medium integration, as well as memory microcircuits.

The tester is designed to perform measurements in the process of acceptance, periodic, certification and other types of IC tests, as well as for incoming inspection

 

FORMULA® 2K provides the requirements of the Russian metrological legislation and regulatory documentation in the field of measurements and tests in microelectronics.

MAIN TECHNICAL SPECIFICATIONS AND FUNCTIONAL CAPABILITIES
FORMULA® 2K TESTERS

 

 

in accordance with the Type Description of Measuring Instruments No. 31123 of April 8, 2013

 

Parameter name                                                                                                                           Ranges and values

The number of bidirectional measuring channels                                                                    64 ... 256
The range of input / output signal levels / amplitude                                                              -10 ... + 10 V / ± 20 V
Frequency control function                                                                                                          20 MHz
clock channel frequency                                                                                                               40MHz                                                         
The duration of the front and the cutoff of the pulse, no more than                                      4 ns / 6 V; 15 ns / 10 V
Memory size of test vectors / errors                                                                                           1 M / 1 M
Active load current                                                                                                                        0.5 ... 24 mA
Output impedance                                                                                                                        50 ohms ± 5 ohms


Sources


The number of sources (including 2 precision)                                                                        3 ... 14
Voltage sources                                                                                                                            -20 ... + 20 V
Voltage setting error                                                                                                                   ± (0.35% + 10) mV
Voltage setting error with precision source from                                                                    ± (0.02% + 1) mV
Source current up to                                                                                                                    2 A
Error limit current                                                                                                                        ± (2% + 1) mA

 

 

Gauges
The number of meters (including 1 precision)                                                                       1 ... 2
Voltage meter                                                                                                                              -20 ... + 20 V
Voltage measurement error of                                                                                                 ± (0.5% + 2) mV
Voltage measurement error with a precision measuring instrument                                  ± (0.02% + 1) mV
Current meter up to                                                                                                                    200 mA
Measurement current accuracy                                                                                               ± (2% + 12) nA
Number of current ranges                                                                                                         6

 


Memory Chips Monitoring                                                                                                        Static RAM